7. Install the air baffle.
8. Install the access panel.
9. Install the front bezel.
10. Do one of the following:
• Server in tower mode: Position the tower server for operation.
• Server in rack mode: Slide the server into the rack.
11. Connect all peripherals cables to the server.
12. Connect each power cord to the server.
13. Connect each power cord to the power source.
14. Power up the server.
15. Ensure all firmware, including option cards and embedded devices, is updated to the same versions
to ensure that the latest drivers are being used.
16. Re-enter any Secure Boot Keys that were previously added in the Secure Boot configuration.
17. Re-enter the server serial number and the product ID (Re-entering the server serial number and
product ID on page 105).
Re-entering the server serial number and product ID
After you replace the system board, the server serial number and the product ID must be configured:
Procedure
1. Access System Utilities. During POST, press F9.
2. On the System Utilities home screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > Advanced Options > Advanced Service Options.
3. Select the Serial Number field and press Enter.
The following alert appears:
The serial number is modified by qualified service personnel and must match
the serial number located on the chassis.
4. Click OK.
5. Type the serial number and press Enter.
6. Select the Product ID field and press Enter.
The following alert appears:
Product ID is modified only by qualified personnel. This value must match
the product ID located on the chassis.
7. Type the product ID and press Enter.
8. Press F10 to save the configuration.
The procedure is complete.
Removal and replacement procedures 105