Tips:
1. If “Error” is displayed on the screen during use, please check the ERROR
CODES and troubleshoot.
2. If the red warning light flashes frequently, it means that there is an error in
the chicken door. Please press the menu button to wake up the screen to
view the error code.
3. If you use the control mode “TIMER-TIMER”, you can wait to verify
whether the auto function is correct.
4. The "LIGHT-LIGHT" control mode can be tested by covering the light
sensor with an opaque material (such as a black cap). After a few seconds,
the door starts going down. Once the door is close to the bottom, remove the
cap and the door will return to the top.
If you disconnect and reconnect the power, the controller will stay in sleep
mode for 30 mins unless you press and go through the settings.
6 7 8
Light operation
Light operation allows users to set when the door will automatically
open and close. The lumen ranges from 0 to 23. The lower the
lumen value is, the weaker the intensity of light will be.
Press (the menu button) to enter setup menu interface.
OPEN LUMEN: 15
CURRENT LUM: 23
Adjust the numerical value of
lumen when the door should
open.
Press the / to adjust
numerical values (15-23).
CLOSE LUMEN: 10
CURRENT LUM: 23
Adjust the numerical value of
lumen when the door should
close.
Press the / to adjust
numerical values (0-14).
05
PROTECT LEVEL
Allow users to adjust protec-
tion levels (0-8 OFF).
Press the / to select levels.
The larger the number
is, the higher the force level
can be.
Press the button
to save the interface and
settings.
09 46
SAVE AND EXIT
Error 3
Error 4
Work
Time Out
Motor
Error!
1.The low battery
causes the door to
open slowly.
Use the new batteries, then
adjust the current time and
save the settings.
2.During the door
opening, the gear
jams causing the
door to open slowly.
3.Obstacles on the
track cause the door
to open slowly.
Check whether there are obst-
acles in the track. If necessary,
add lubricating oil or grease to
the track. Finally, press the
button to clear the error.
4.The door's top or
bottom magnet has
fallen off.
Pull out the front panel and rein-
stall the magnet, and then press
the button after the install-
ation is complete. Please cont-
act us if the magnet is missing.
The motor is
abnormal.
1.Check if the motor lead is
broken or the plug is not insert-
ed. Reconnect the motor leads
or plug.
2.If the error still occurs after
troubleshooting, please send
the device for repairs.
Make sure that the gear is not
blocked by any objects.
Finally, press the button to
clear the error.
Error code
Error 1
Error 2
Panel
out!
Open
Blocked
Close
Blocked
1.Front
panel
Check if the front panel is
installed correctly. If not,
please install it and fix the
4 screws on the both sides.
2.The position
sensor does not
sense the mag-
net on the door.
3.The door's top
magnet has
fallen off.
Pull out the front panel to let the
door falls to the bottom and
ensure that there is no foreign
matter at the bottom of the door,
then push the panel back and
screws it.
Install the magnet and contact
us if it is missing.
4.The internal
position sensor
has failed.
If the error still occurs after
"1,2,3", please send the device
for repairs.
5.PCB board is
faulty.
Door blocked
when opening.
If the error still occurs after
"1,2,3", please send the device
for repairs.
Door blocked
when closing.
The door's top
magnet has
fallen off.
Reason Solution
1.Check if there are obstacles at
the bottom of the door.
2.Check whether there are
obstacles in the track.
3.If no obstacles, please add
lubricating oil or grease to the track.
4.Increase the protection level.
Finally, press the button to
clear the error.
1.Check whether the gear is
jammed by the wooden board.
2.Check whether there are obst-
acles in the track.
3.If no obstacles, please add
lubricating oil or grease to the track.
Finally, press the button to
clear the error.
Please install the magnet,then
press the button to clear the
error. Please contact us if the
magnet is missing.
Display
Part G Product Parameter
Product name
Working mode
Lid material
Door material
Product size
Power supply
Supply voltage
Warranty
Automatic chicken coop door
Light sensitive & timer
ABS
Aluminum & galvanized steel
31 x 42 x 30cm
4pcs AA battery / 6V battery
6 V
2 years
Part F Trouble Shooting
CHICKEN COOP OPENER
AD006 USER MANUAL
Question and Answer IconNeed help?

Do you have a question about the HPS FENCE AD006 and is the answer not in the manual?

Summary

Product Composition

Installation

Panel Introduction

Programming Guidelines

Button Usage

Explains the function of each button on the control panel for setting and operation.

Chicken Coop Door Programming

Clock Setup

Instructions for setting the device's current time and initializing clock setup.

Timer Operation

How to configure automatic opening and closing times using timer settings.

Light Operation

Setting the door to open or close based on ambient light intensity levels.

Trouble Shooting

Panel Issues (Error 1)

Troubleshooting steps for panel-related errors, including sensor and magnet problems.

Blocked Door Issues (Error 2)

Solutions for the door getting blocked during opening or closing operations.

Slow Door Operation (Error 3)

Addressing issues causing slow door movement, such as low battery or gear jams.

Motor Errors (Error 4)

Diagnosing and resolving motor-related faults and abnormal operation.

Product Parameter

Overview

This document describes the AD006 Chicken Coop Opener, an automatic chicken coop door designed to provide convenience and security for poultry owners.

Function Description

The AD006 Chicken Coop Opener is an automatic door system for chicken coops. It offers both timer-based and light-sensitive operation modes, allowing users to customize when the door opens and closes. The device includes a control panel with a display that shows the current time, battery level, and operational settings. It features a warning light to indicate issues and a light sensor for the light-sensitive mode. The door is designed to open and close automatically, providing protection for chickens and convenience for owners.

Important Technical Specifications

  • Product Name: Automatic chicken coop door
  • Working Mode: Light sensitive & timer
  • Lid Material: ABS
  • Door Material: Aluminum & galvanized steel
  • Product Size: 31 x 42 x 30cm
  • Power Supply: 4pcs AA battery / 6V battery
  • Supply Voltage: 6 V
  • Warranty: 2 years

Usage Features

The AD006 offers several user-friendly features for installation, programming, and operation:

Installation:

  1. Recommended Door Size: The recommended opening size for installation is 15.5" (39.37cm) high x 10" (25.4cm) wide.
  2. Leveling: It is crucial to use a level to ensure the door is installed straight. Four screws are used to secure the door to the left and right side rails.
  3. Controller Access: Four fixing screws on both sides of the controller need to be removed to access internal components. The sensor position should be on the left.
  4. Battery Installation: The cover can be gently removed to install 4 AA batteries or one 6V battery. High-quality batteries like Duracell or Panasonic are recommended.
  5. Preventing Tilting: After opening the door by pressing the 'open' button, two screws should be installed 10cm above the controller to prevent the door from tilting. Care must be taken not to obstruct the aluminum door with the screws.
  6. Gear Clearance: After installation, ensure the gear of the chicken door is not blocked by anything.

Panel Introduction and Button Usage: The control panel features a display, a warning light, and a light sensor. There are three main buttons:

  • Button 1 (Menu/Setting): Used to switch between setting hours and minutes, and to adjust values (in conjunction with the A/V buttons). Also used to enter setup menu interface for timer and light operations.
  • Button 2 (Close/Decrease/Mode):
    • Click to temporarily close the door manually (it will open automatically after 3 minutes).
    • Decreases values during programming.
    • Switches between working modes (TIMER-TIMER and LIGHT-LIGHT).
  • Button 3 (Open/Increase):
    • Click to temporarily open the door manually (it will close automatically after 3 minutes).
    • Increases values during programming.

Programming Guidelines:

  • Clock Setup: Press and hold Button 1 for 2 seconds to initialize clock setup. Use Button 1 to scroll between hours and minutes, and the A/V buttons to adjust values.
  • Timer Operation (TIMER-TIMER mode):
    • Press Button 1 to enter the setup menu interface.
    • Use the A/V buttons to switch between TIMER-TIMER and LIGHT-LIGHT modes.
    • Open Up Time: Press Button 1 to scroll between hours and minutes, then use A/V buttons to select the open time.
    • Close Down Time: Press Button 1 to scroll between hours and minutes, then use A/V buttons to adjust the close time.
  • Light Operation (LIGHT-LIGHT mode):
    • Press Button 1 to enter the setup menu interface.
    • Open Lumen: Adjust the numerical value of lumen (15-23) when the door should open using the A/V buttons. Lower lumen value indicates weaker light intensity.
    • Close Lumen: Adjust the numerical value of lumen (0-14) when the door should close using the A/V buttons.
  • Protection Level: Allows users to adjust protection levels from 0-8 (OFF). Use the A/V buttons to select levels. A larger number indicates a higher force level.
  • Save and Exit: Press Button 1 to save the interface and settings.

Maintenance Features

The manual provides a detailed troubleshooting guide for common issues, categorized by error codes:

Error 1: Panel out!

  • Front panel not installed correctly: Check and fix the 4 screws on both sides.
  • Position sensor not sensing magnet: Pull out the front panel, let the door fall to the bottom, ensure no foreign matter, then push the panel back and screw it.
  • Door's top magnet fallen off: Install the magnet; contact support if missing.
  • Internal position sensor failed: Send the device for repairs.
  • PCB board faulty: Send the device for repairs.

Error 2: Open Blocked / Close Blocked

  • Door blocked when opening/closing:
    • Check if the gear is jammed by the wooden board.
    • Check for obstacles in the track.
    • If no obstacles, add lubricating oil or grease to the track.
    • For closing issues, increase the protection level.
    • Press Button 1 to clear the error.
  • Door's top magnet fallen off: Install the magnet, press Button 1 to clear the error; contact support if missing.

Error 3: Work Time Out

  • Low battery: Use new batteries, adjust current time, and save settings.
  • Gear jams during opening: Ensure no objects block the gear. Press Button 1 to clear the error.
  • Obstacles on track: Check for obstacles, add lubricating oil/grease if needed. Press Button 1 to clear the error.
  • Door's top or bottom magnet fallen off: Pull out front panel, reinstall magnet, press Button 1 after installation. Contact support if missing.

Error 4: Motor Error!

  • Motor abnormal:
    • Check if motor lead is broken or plug is not inserted. Reconnect motor leads or plug.
    • If error persists after troubleshooting, send device for repairs.

General Tips:

  • If "Error" is displayed, check error codes and troubleshoot.
  • Frequent flashing of the red warning light indicates an error; press Button 1 to view the error code.
  • To verify "TIMER-TIMER" mode, wait for auto function.
  • To test "LIGHT-LIGHT" mode, cover the light sensor with an opaque material. The door should go down; removing the cover should make it return to the top.
  • If power is disconnected and reconnected, the controller will stay in sleep mode for 30 minutes unless a button is pressed and settings are navigated.

HPS FENCE AD006 Specifications

General IconGeneral
BrandHPS FENCE
ModelAD006
CategoryFarm Equipment
LanguageEnglish