Doc. No. DOC-00045020
REV.
Issued Date 2008/07/14
.
Revised Date 2008/10/20
A04
Doc. Title
Dream Service Manual
Page 87 of 113
HTC CONFIDENTIAL
HTC Corporation
¾ The inspection condition of Newton ring:
a. Inspection distance: 30cm / Inspection time: 5 sec
b. Ambient illumination is to be 500-1000 Lux (Incandescent lamp)
c. Inspection should be performed under the condition that LCD screen could reflect the mirror image of
lamp.
d. The criteria of Newton ring’s tinges and measure of area must follow up the worst-case sample.
e. The area of Newton ring is smaller than 10 * 10 square mm.
Display inspection
Inspection Defects Accept Level Level
Single
Red+ Green+ Blue 3, S >
5mm.
Minor
2 adjacent 0 Minor
Bright
Dots
3 or more
adjacent
0 Minor
Single
Total Number 2, S >
5mm.
Minor
Dark Dots
2 adjacent 0 Minor
Dark or Bright lines 0 Minor
A
ll Allowable Dots Defects
Total Number 3, S >
5mm.
Minor
Electrical Characteristic
Defects
Shift and tilt of screen
viewed area
The black edge around display area must
be detected by front view.
Minor
Scratch
0.03 < W 0.1 (mm)
L 5 (mm), N 2 (mm)
Minor
Lint (linear foreign objects)
0.03 < W 0.1 (mm)
0.3 < L 3.0 (mm)
N 5
Minor
Spots 0.1 < D 0.3 (mm), N 4 ≦≦ Minor
Fish eye on film 0.1 < D 0.4 (mm), N ≦≦ 4 Minor
Breakage on film surface Not acceptable Minor
Foreign Scratch,
Objects or Lint
on power off
status
Total acceptable defect quantity 10 Minor
6.2. Main unit inspection
GAP INSPECTIONS
Description
Accept Criteria
1.
Gap between each key and
ME parts.
Can’t stuck up or no click feeling.
It couldn’t allow stuck up at pressing process.
2.
Gap between all generic ME
parts
Gap between all generic ME parts < 0.4 mm