Figure 5-59 Installing the flexible NIC
Step 11 Tighten the two screws using the Phillips screwdriver to secure the NIC. See (2) in Figure
5-59.
Step 12 Connect the network cables to the NIC.
Step 13 Install the drive module (see 5.16 Rear Drive Module) or riser card module (see 3.13
Installing a Riser Card Tray) above the NIC.
Step 14 Install the chassis cover. For details, see 3.5 Installing the Chassis Cover.
Step 15 Install the server. For details, see 4.4 Installing the Server on Guide Rails.
Step 16 Connect the power cables. For details, see 5.4 PSU.
Step 17 Power on the server. For details, see 3.1 Powering On the Server.
Step 18 Log in to the iBMC WebUI, and check whether the new component is normal. For details, see
the Huawei Rack Server iBMC User Guide.
----End
5.16 Rear Drive Module
To install a rear drive module, perform the following steps:
Step 1 Wear an ESD wrist strap. For details, see 12 Preventing Electrostatic Discharge.
2288H V5 Server
User Guide
5 Optional Part Installation
Issue 04 (2018-09-04) Copyright © Huawei Technologies Co., Ltd. 169