EasyManua.ls Logo

Huawei 2288H V5 - Nvme SSD Indicators

Huawei 2288H V5
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 2-9 SAS/SATA drive indicators
Indicator State Description
Drive fault indicator
l Steady yellow: The drive is not detected, the drive is faulty,
or the RAID array status of the drive is abnormal.
l Blinking yellow: The server is locating the drive or
rebuilding RAID.
l Off: The drive is operating normally.
NOTE
If the fault indicator is steady yellow, use the OS CLI to check the
RAID status to determine whether the RAID array status is abnormal
or whether the drive is faulty. For details about command description,
see the Huawei V5 Server RAID Controller Card User Guide.
Drive activity indicator
l Steady green: The drive is inactive.
l Blinking green: Data is being read from the drive, written to
the drive, or synchronized between drives.
l Off: The drive is not detected or is faulty.
2.9.3 NVMe SSD Indicators
Figure 2-44 shows the NVMe SSD indicators.
Figure 2-44 NVMe SSD indicators
Table 2-10 NVMe SSD indicators
Green Indicator
Yellow
Indicator
State Description
Off Off The NVMe SSD cannot be detected.
Steady green Off The NVMe SSD is detected and working
properly.
Blinking green (2
Hz)
Off Data is being read from or written to the NVMe
SSD.
Off Blinking yellow
(2 Hz)
The NVMe SSD is being located or hot-swapped.
Off Blinking yellow
(0.5 Hz)
The NVMe SSD completes the hot removal
process and is removable.
Steady green or
off
Steady yellow The NVMe SSD is faulty.
2288H V5 Server
User Guide
2 Components
Issue 04 (2018-09-04) Copyright © Huawei Technologies Co., Ltd. 31

Table of Contents

Related product manuals