3.5 Installing the Chassis Cover
Step 1 Wear an ESD wrist strap. For details, see 12 Preventing Electrostatic Discharge.
Step 2 Aligning the cover with the fixing slots on chassis walls, put it down and close the handle.
See (1) and (2) in Figure 3-9.
Figure 3-9 Installing the chassis cover
Step 3 Tighten the screw using a flat-head screwdriver to secure the handle. See (3) in Figure 3-9.
Step 4 Install the server. For details, see 4.4 Installing the Server on Guide Rails.
Step 5 Connect the power cables. For details, see 5.4 PSU.
Step 6 Power on the server. For details, see 3.1 Powering On the Server.
----End
3.6 Removing a Fan Module
Step 1 Wear an ESD wrist strap. For details, see 12 Preventing Electrostatic Discharge.
2288H V5 Server
User Guide
3 Basic Operations
Issue 04 (2018-09-04) Copyright © Huawei Technologies Co., Ltd. 51