4: LAN port cable, which is connected to a computer with a network cable (RJ45 connectors).
5: Ground cable. The M4 connector is connected to the AR150/200 and the M6 connector is
connected to ground. The cable is in yellow and green.
l When the AR150/200 is placed on the desktop or installed in a cabinet/rack, the ground
cable is connected facing downwards, as shown in Figure 2-1 a. The ground cable cannot
interfere with other devices in the cabinet/rack.
l When the AR150/200 is wall mounted, the ground cable is connected facing left, as shown
in Figure 2-1 b.
6: external power adapter, which is connected to the AC power supply to output DC power to
the device.
Power adapter output power:
l AR150 & AR200 series: 36 W
NOTE
The AC power cable must be secured using a latch.
7: A whip antenna, which is installed on a 3G interface to transmit and receive 3G signals.
8: A SIM card, which is installed in the SIM card slot of a device to allow the device to connect
to a 3G network.
2.4 Powering on the Device
This section provides the checklist used to check the AR150/200 before powering on it.
Checklist
No.
Item Method
1 The power cables and ground cables are copper wires, and
are not spliced or damaged. The cables are safely
connected and in compliance with standards.
View
2 The power cables and ground cables are connected safely.
The spring washers of the ground cable terminals are on
the flat washer.
View
3 All signal cables to be deployed pass the continuity check. Measure
4 No signal cables are near the cabinet's heat vents. View
5 The bent part of signal cables cannot be too tight. View
6 The cables in the cabinet are not crossed and the cables
outside the cabinet are bundled.
View
7 Both ends of signal cables are clearly labeled and the label
text is in the same direction.
View
Huawei AR150&200 Series Enterprise Routers
Quick Start Guide 2 Product Installation