l Transmission rate of the console user interface: 4800 bit/s
l Flow control mode of the console user interface: None
l Parity of the console user interface: even
l Stop bit of the console user interface: 2
l Data bit of the console user interface: 8
l Timeout period for disconnecting from the console user interface: 30 minutes
l Number of lines that a terminal screen displays: 30
l Size of the history command buffer: 20
l User authentication mode: password (password: huawei)
Procedure
Step 1 Set physical attributes of the console user interface.
<Huawei> system-view
[Huawei] user-interface console 0
[Huawei-ui-console0] speed 4800
[Huawei-ui-console0] flow-control none
[Huawei-ui-console0] parity even
[Huawei-ui-console0] stopbits 2
[Huawei-ui-console0] databits 8
Step 2 Set terminal attributes of the console user interface.
[Huawei-ui-console0] shell
[Huawei-ui-console0] idle-timeout 30
[Huawei-ui-console0] screen-length 30
[Huawei-ui-console0] history-command max-size 20
Step 3 Set the user authentication mode in the console user interface to password.
[Huawei-ui-console0] authentication-mode password
[Huawei-ui-console0] set authentication password simple huawei
[Huawei-ui-console0] quit
After the console user interface is configured, a user in password authentication mode can log
in to the router through a console port, implementing local maintenance of the router. For details
on how a user logs in to the router, see the 5 Configuring User Login.
----End
Configuration Files
#
sysname Huawei
#
user-interface con 0
authentication-mode password
user privilege level 15
set authentication password simple huawei
history-command max-size 20
idle-timeout 30 0
screen-length 30
databits 8
parity even
stopbits 2
speed 4800
screen-length 30
#
return
Huawei AR2200 Series Enterprise Routers
Configuration Guide - Basic Configuration 4 Configuring User Interface
Issue 02 (2011-10-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.