EasyManua.ls Logo

Huawei AR550 Series - Page 21

Huawei AR550 Series
505 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The DI/DO interfaces are used to detect voltage level signals or deliver instructions. Table
3-15 lists DI/DO interface attributes.
Table 3-15 DI/DO interface attributes
Attribute Description
Connector type RJ45
Signal type LVTTL voltage level, digital input/output
Cable type 6.2.7 RJ-45 Connector (DI/DO)
RS485/RS422 interface
The RS485/RS422 interface can be connected to a meter or monitoring terminal. Table 3-16
lists RS485/RS422 interface attributes.
Table 3-16 RS485/RS422 interface attributes
Attribute
Description
Connector type 5-pin Phoenix terminal block
Standards compliance RS485/RS422
Working mode
l RS485: half-duplex
l RS422: full-duplex
Communication distance 1 km (> 19 kbit/s)
Baud rate 1200/2400/4800/9600/115200
Cable type 6.2.8 5-Pin Phoenix Connector (RS485/
RS422)
Heat Dissipation
The AR502EG-L router has no fans and uses natural heat dissipation.
Technical Specifications
Table 3-17 lists technical specifications of the AR502EG-L router.
Table 3-17 AR502EG-L technical specifications
Item
Specification
System parameters
Processor Dual-core, 700 MHz
Huawei
AR500&AR510&AR531&AR550&1500&AR2500
Industrial Switch Routers
Hardware Description
3 Chassis
Issue 10 (2019-03-06) Copyright © Huawei Technologies Co., Ltd. 92

Other manuals for Huawei AR550 Series