BBU Hardware
1. Exterior of the BBU
2. Configuration Principles of the BBU Boards
Board Mandatory/
Optional
Full Configuration Installation
Slot
Remarks
GTMU Mandatory 1 S5 and S6 Can be installed only in S5 and S6.
UPEU Mandatory 2 S18 or S19 A single UPEU is preferentially configured
in the S19 slot.
FAN Mandatory 1 S16 Can be installed only in the S16 slot.
UTRP Optional 1 S0 or S4 Preferentially installed in the slot4.
UELP Optional 2 S0 or S4 A single UELP is preferentially configured
in the S4 slot.
UFLP Optional 2 S0 or S4 A single UELP is preferentially configured
in the S4 slot.
USCU Optional 1 S0 or S1 Preferentially installed in the S1 slot.
UEIU Optional 1 S18 Preferentially installed in the S18 slot.
z The UELP and UFLP need to be optionally configured in the BBU or SLPU on site according to the field
requirements.
z UTRP is supported in V300R012 and later versions.