Indicator Status Meaning Diagnosis Procedure
transmission
status indicator for
a 10GE electric
port
Blinking
green
Data is being
transmitted.
O The network port is
not connected.
1. Connect the port
to another switch,
optical ber, and
optical module to
check whether the
original switch
and optical
ber
are normal and
whether the type
and speed of the
original optical
module are
correct.
2. Check whether
the ports on the
switch and NIC
are up.
3. Check whether
the NIC is
operating
properly.
Data transmission
rate indicator for a
10GE electrical
port
Steady
yellow
The link rate is 1
Gbit/s.
1. Connect the port
to another switch,
optical ber, and
optical module to
check whether the
original switch
and optical
ber
are normal and
whether the type
and speed of the
original optical
module are
correct.
2. Check whether
the ports on the
switch and NIC
are up.
3. Check whether
the NIC is
operating
properly.
Steady
green
The link rate is 10
Gbit/s.