Indicator Status Meaning Diagnosis
Fault diagnosis
panel on the
RH5885 V3 server
Steady red A fault alarm is
generated for the
server
component.
For details, see
"Indicators and
Buttons" in the
RH5885 V3
Server V100R003
User Guide
.
O The server
component is
operating
properly.
N/A
Indicators Available Only on the RH8100 and X6800
Table 5-12 Indicators for each module
Indicator Status Meaning Diagnosis
RH8100 V3 fan
module indicator
Steady green The fan module
hardware or
backplane is
faulty or the fan
module software
is performing an
online upgrade.
(An online
upgrade takes
about 3 minutes.)
Check whether
the fan module
hardware or
backplane is
faulty and
whether the fan
module software
is performing an
online upgrade.
Blinking green
(once every 2
seconds)
The fan module is
properly
communicating
with the iBMC.
N/A