25
www.huawei.com Huawei Confidential 25
SuperMicro: SYS-4028GR-TXRT (NVLink)
2S + 24DIMM, CPUs with
active heat dissipation
2*PCIe x8 slots
The CPUs provide 2*PCIe x8, which
are alternatively supported with the
hard drive RAID and NVMe.
Parameter G5500-G560 SuperMicro 4028GR-TXRT
Dimensions (H x W x D)
4U (175*447*790) 4U
Architecture Modular Modular
CPU 2S + 24DIMM 2S + 24DIMM
Maximum CPU power 145 W 145 W
GPU 8*P100/P40/P4 8*P100 NVLink
Maximum GPU power 350 W 300 W
CPU:GPU topology 1:8/1:4 flexible configuration 1:8
Hard drive
6*2.5'' NVMe SSD
2*2.5'' SAS/SATA HDD
8*3.5'' HDD
16*2.5'' SSD/HDD (8*NVMe SSD)
RAID RAID 0/1/10/5/50/6/60 RAID 0/1/10/5/50/6/60
PCIe expansion 4*PCIe x16 4*PCIe x16 (2*PCIe x8 and hard drive
RAID/NVMe alternatively supported)
On-board network adapter
Power supply 4400 W hot swap, 2+2 4000 W hot swap, 2+2
Fan 6 hot swap, 5+1 8 hot swap, 7+1
Temperature
5°C to 35°C 10°C to 35°C
Beating Points
The 8 NVMe SSDs are restricted by the PCIe x8 links, and only two drives support line
rate.
The power supply capability is limited and cannot be evolved.
Active heat dissipation for the CPUs (many failure points)
The power module is integrated into the fan and has to be inserted and removed at the
same time during maintenance, which makes maintenance inconvenient.