Procedure (on the BIOS)
Step 1 Restart the server, and enter the BIOS.
For details, see 9.6 Accessing the BIOS.
Step 2 Choose Advanced > IPMI iBMC Configuration and press Enter.
The IPMI iBMC Configuration screen is displayed.
Step 3 Select iBMC Configuration and press Enter.
The iBMC Configuration screen is displayed, showing the iBMC IP address.
Step 4 Select IPv4 IP Address and press Enter.
The IPv4 IP Address dialog box is displayed.
Step 5 Change the IPv4 address of the iBMC management network port.
Step 6 Press F10.
Save the settings and exit.
----End
7.4.6 Configuring RAID
The 2288H V5 supports multiple types of RAID controller cards.
l Use Intelligent Computing Compatibility Checker to obtain information about the
compatible RAID controller cards.
l The configuration method varies depending on the RAID controller card model. For
details, see Huawei V5 Server RAID Controller Card User Guide.
7.4.7 Configuring the BIOS
Scenarios
This section describes how to configure the BIOS of the server.
To configure the BIOS, perform the following operations:
l Set the system boot sequence
l Set PXE for a NIC
l Set the BIOS password
l Select a language
For details about other configurations, see Huawei Server Purley Platform BIOS
Parameter Reference.
FusionServer Pro 2288H V5 Server
User Guide
7 Installation and Configuration
Issue 08 (2019-10-30) Copyright © Huawei Technologies Co., Ltd. 109