● On the iBMC CLI, run the ipmcget -d version command to obtain the
information.
Step 2 Check the iBMC and BIOS congurations.
After the mainboard is replaced, the original iBMC or BIOS conguration will be
lost. If the current iBMC or BIOS parameters have been adjusted based on service
scenarios, ensure that the parameter
conguration is the same as that before the
mainboard is replaced to ensure that services are not aected after the mainboard
is replaced.
Step 3 Export the iBMC or BIOS conguration les.
For details, see
FusionServer Pro X6000 Server iBMC User Guide
.
● The iBMC supports import and export of conguration les from version 2.32.
● After replacing the mainboard, import the iBMC and BIOS conguration les that are
exported from the iBMC. However, the exported conguration le does not contain
password information. You need to manually congure the password for the iBMC user.
For details about how to import and export the conguration le, see
FusionServer Pro
X6000 Server iBMC User Guide
.
● The iBMC and BIOS
conguration les exported from the iBMC contain the
conguration list. For details, see "Conguration File Description" in
FusionServer Pro
X6000 Server iBMC User Guide
.
● If the iBMC and BIOS conguration les are not exported before the mainboard is
replaced, manually congure the iBMC and BIOS data after replacing the mainboard.
Step 4 Power o the server node.
For details, see 8.3.2
Power-O Procedure.
Step 5 Remove the server node.
For details, see 8.3.3 Removing an XH321 V5.
Step 6 Place the server node on the ESD workstation.
Step 7 Remove the air duct.
For details, see 8.4.23 Removing the Air Duct.
Step 8 Determine the position of the mainboard and the server node case.
FusionServer Pro XH321 V5 Server Node
Maintenance and Service Guide 8 Parts Replacement
Issue 17 (2021-03-09) Copyright © Huawei Technologies Co., Ltd. 98