EasyManua.ls Logo

Huawei LUNA2000-2.0MWH-2H1 - Connecting Socket Circuit Wires

Huawei LUNA2000-2.0MWH-2H1
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. Cable Type Conductor Cross-
Sectional Area
Range
Outer
Diameter
Termin
al
Source
2 AC
input
power
cable
Four-core/Five-
core outdoor
copper/copper-
clad aluminum/
aluminum alloy
cable
LUNA2000-2.0M
WH-1HX: 35–185
mm
2
LUNA2000-2.0M
WH-2HX: 10–185
mm
2
24.6–72 mm M10
OT/DT
termina
l
Prepared
by the
customer
4 FE
commu
nication
s cable
CAT 5E outdoor
shielded network
cable, internal
resistance ≤ 1.5
ohms/10 m
- < 9 mm Shielde
d RJ45
connect
or
Prepared
by the
customer
5 Optical
cable
Supports the
four-core or
eight-core
single-mode
armored cable
with the
transmission
wavelength of
1310 nm.
- ≤ 18 mm - Prepared
by the
customer
5.2 Connecting Socket Circuit Wires
Scenario 1
This procedure applies only to the models listed in the table below.
Models
Air Conditioner Position in the
Battery Cabin
LUNA2000-2.0MWH-1HX 1/3/5/7/9/11
LUNA2000-2.0MWH-2HX 1/4/7/10
NO TE
Cables 1733, 1735, 1734 and 1736 are pre-installed. Cables 1751, 1752, 1757, 1760,
2055, 2056, 1761 and 1762 need to be installed.
The cables to be installed can be obtained from the cable binding position shown in the
gure before installing the socket.
LUNA2000-2.0MWH Series Smart String ESS
User Manual 5 Installing Cables
Issue 08 (2022-11-15) Copyright © Huawei Technologies Co., Ltd. 113

Table of Contents

Related product manuals