Figure A-1 Requirements on an OT or DT terminal
Crimping an OT or DT Terminal
NO TICE
Avoid scratching the core wire when stripping a cable.
The cavity formed after the conductor crimp strip of the OT or DT terminal has
been crimped must wrap around the core wire completely. The core wire must
make close contact with the OT or DT terminal.
Wrap the wire crimping area with heat shrink tubing or insulation tape. The
heat shrink tubing is used as an example.
Use a heat gun carefully to avoid heat damage to the equipment.
LUNA2000-(97KWH-1H1, 129KWH-2H1,
161KWH-2H1, 200KWH-2H1) Smart String ESS
User Manual A Crimping an OT or DT Terminal
Issue 10 (2023-11-07) Copyright © Huawei Digital Power Technologies Co., Ltd. 165