Technical
Specications
Door Status Sensor
Startup distance 25–45 mm
Rated Power 10 W
Securing method Screw
Hole spacing 40 mm±0.8 mm
Switch voltage 100 V DC (Max)
Contact withstand
voltage
150 V DC (Max)
Impedance 0.3 Ω
Switch status Steady on
Outer material White acrylonitrile butadiene styrene (ABS)
engineering plastic
2.4.3.4 Electrode Water Sensor
The water sensor detects water based on the resistance change between both
electrodes.
When the electrodes detect water, they are short-circuited and the CMU reports an
alarm.
Figure 2-18 Appearance
Technical
Specications Electrode Water Sensor
Operating temperature –40°C to +80°C
Storage temperature –40°C to +80°C
LUNA2000-(97KWH-1H1, 129KWH-2H1,
161KWH-2H1, 200KWH-2H1) Smart String ESS
User Manual 2 Product Description
Issue 10 (2023-11-07) Copyright © Huawei Digital Power Technologies Co., Ltd. 44