HUAWEI ME906s LTE M.2 Module
Hardware Guide
Description of the Application Interfaces
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3.11.2 Coaxial RF Connector Guidelines
The antenna interface must be used with coaxial cables with characteristic
impedance of 50 Ω.
The ME906s module supports the buckled RF connector antenna connection
methods: buckled RF connector 818000500 by ECT, RFC43-1K2600 by ACON
or other equivalent connectors.
Figure 3-24 shows the RF connector dimensions.
Figure 3-24 RF connector dimensions
Table 3-17 The major specifications of the RF connector
Temperature range:
–40°C to +85°C
There are two kinds of coaxial cables (0.81 mm and 1.13 mm) mating the RF
connector in the ME906s. 1.13 mm cable is recommended.