EasyManua.ls Logo

Huawei MU609 - Page 59

Huawei MU609
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HUAWEI MU609 HSPA LGA Module
Hardware Guide
Electrical and Reliability Features
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
59
Item
Test Condition
Standard
Sample
size
Results
Thermal shock
Low temperature: 40ºC
High temperature: 85ºC
Temperature change
interval: < 20s
Operation mode: no
power
Test duration: 100 cycles;
15 min+15 min/cycle
JESD22-
A106-B
3 pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Salty fog test
Temperature: 35°C
Density of the NaCl
solution: 5%±1%
Operation mode: no
power, no package
Test duration:
Spraying interval: 8 h
Exposing period after
removing the salty fog
environment: 16 h
JESD22-
A107-B
3 pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Sine vibration
Frequency range: 5 Hz to
200 Hz
Acceleration: 1 Grms
Frequency scan rate: 0.5
oct/min
Operation mode: working
with service connected
Test duration: 3 axial
directions. 2 h for each
axial direction.
Operation mode: working
with service connected
JESD22-
B103-B
3 pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok
Shock test
Half-sine wave shock
Peak acceleration: 30
Grms
Shock duration: 11 ms
Operation mode: working
with service connected
Test duration: 6 axial
directions. 3 shocks for
each axial direction.
Operation mode: working
with service connected
JESD-B1
04-C
3 pcs/group
Visual inspection: ok
Function test: ok
RF specification: ok

Table of Contents