– Select Monthly and set Date and execution start time. For example, if Date: 2 and
30 are specified, and Time: 12:10 is specified, then timing snapshot will be
executed at 12:10 on dates 2 and 30 every month.
3. Click OK.
Step 6 Optional: Modify advanced properties of the file system.
1. Click Advanced.
The Advanced dialog box is displayed.
2. Set advanced properties of the file system.
Click the Properties, Tuning and WORM tabs and set related parameters. Table 4-13,
Table 4-14 and Table 4-15 describe related parameters.
Table 4-13 Property parameters
Parameter
Description Value
Owning
Controller
Controller to which the file system
belongs. You are advised to allocate file
systems to different controllers for load
balancing.
NOTE
If you are not sure about the owning
controller, select Auto Select. The storage
system will automatically select the owning
controller for file systems.
[Value range]
Based on actual conditions
of available controllers of
the storage device.
[Example]
Auto select
[Default]
Auto select
Capacity
Alarm
Threshold
(%)
Alarm threshold of the file system
capacity.
[Value range]
The value is an integer
ranging from 50 to 95.
[Example]
90
[Default]
90
OceanStor V3 Series
HyperMetro Feature Guide for File
4 Configuration
Issue 05 (2018-01-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
101