Figure 4-31 Indicators on the front panel of a 2 U 12-disk controller enclosure
1 Running indicator of
the disk module
2 Location/Alarm
indicator of the disk
module
3 Location indicator
of the controller
enclosure
4 Alarm indicator of
the controller
enclosure
5 Power indicator/
Power button of the
controller enclosure
- -
Table 4-11 describes the indicators on the front panel of a controller enclosure.
Table 4-11 Description of the indicators on the front panel of a controller enclosure
Module
No. Indicator Status and Description
Disk
module
1 Running indicator of the
disk module
l Steady green: The disk module is
working correctly.
l Blinking green: Data is being
read and written on the disk
module.
l Off: The disk module is powered
off or powered on incorrectly.
2 Location/Alarm indicator of
the disk module
l Steady red: The disk module is
faulty.
l Blinking red: The disk module is
being located.
l Off: The disk module is working
correctly or hot swappable.
System
subrack
3 Location indicator of the
controller enclosure
l Blinking blue: The controller
enclosure is being located.
l Off: The controller enclosure is
not located.
OceanStor 2600 V3
Product Description
4 Hardware Architecture
Issue 09 (2019-05-15) Copyright © Huawei Technologies Co., Ltd. 45