Connecting the storage system to the network
The controller enclosure can be connected to application servers using front-end ports.
5110 V5/5300 V5 supports the following types of front-end ports: 8 Gbit/s FC, 16 Gbit/s FC, 32 Gbit/s
FC, 10 Gbit/s Ethernet, 10 Gbit/s FCoEGE electrical, 10GE electrical, 25 Gbit/s Ethernet, 40 Gbit/s
Ethernet, and 100 Gbit/s Ethernet.
5500 V5 supports the following types of front-end ports: 8 Gbit/s FC, 16 Gbit/s FC, 32 Gbit/s FC, 10
Gbit/s Ethernet, 10 Gbit/s FCoE, GE electrical, 10GE electrical, 25 Gbit/s Ethernet, 40 Gbit/s Ethernet,
100 Gbit/s Ethernet, and 56 Gbit/s IB.
10GE electrical interface modules support GE/10GE auto-sensing.
The following figures are an example of cable connections. The details like cable appearance and types of
interface modules may be different from those at your site
The following figures show the connections by network cables and optical fibers. For details, see OceanStor
5000, 5000F, 6000, and 6000F V5 Series V500R007 Installation Guide.
Scenario 1 Directly connecting front-end ports to the application server
Network cable connection
Optical fiber cable connection
17
Application server
Controller enclosure
Application server
Controller enclosure