EasyManua.ls Logo

Huawei OceanStor V5 Series - Replacing a Management Module; Replacing a Management Module (for 5600 V5;5800 V5;5600 F V5;5800 F V5)

Huawei OceanStor V5 Series
278 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 13 Conrm the replacement.
1. Perform a post-replacement inspection.
After the parts replacement, return to the SmartKit page and click Replaced.
Then complete the parts check after the replacement as prompted.
2. Check system status.
On the Parts Replacement page, click Inspection to check the system status
again. If any item fails inspection, rectify the fault based on the suggestions in
the inspection report.
3. After the preceding procedure is complete, check services on the host for
storage-related errors.
----End
Follow-up Procedure
After the 8 Gbit/s Fibre Channel interface module (eight ports) is replaced, label it
to facilitate subsequent operations.
7.9 Replacing a Management Module
This section describes how to replace a management module.
7.9.1 Replacing a Management Module (for 5600 V5/5800
V5/5600F V5/5800F V5)
This section describes how to replace a management module.
Impact on the System
During the replacement of a management module, the service processing
capability is adversely
aected.
Prerequisites
A spare part is on hand.
The management module that you want to replace has been located.
You can locate a component in either of the following ways:
Locating a component based on alarms in DeviceManager: On the Alarms and Events
page of DeviceManager, view the help information and determine the ID of the
component to be replaced. Then locate the component at your site based on its ID.
Locating a component based on the status of its Running/Alarm indicator: For details
about the indicators on dierent components, see Indicator Introduction of each
component in the
Product Description
specic to your product model and version.
Services running on the management module that you want to replace have
been stopped.
The cable connection positions of the management module that you want to
replace are labeled on the cables.
OceanStor V5 Series
Parts Replacement 7 Replacing FRUs
Issue 15 (2019-12-30) Copyright © Huawei Technologies Co., Ltd. 236

Table of Contents

Related product manuals