XGigabitEthernet0/0/2 Slave Inactive 0 0000/00/00 00:00:00 UTC
+00
:00
[SwitchA] display monitor-link group 1
Monitor Link group 1 information :
Recover-timer is 10 sec.
Member Role State Last-up-time Last-down-tim
e
Smart-link1 UpLk UP 0000/00/00 00:00:00 UTC+00:00 0000/0
0/00 00:00:00 UTC+00:00
XGigabitEthernet0/0/3 DwLk[1] DOWN 0000/00/00 00:00:00 UTC+00:00 0000/0
0/00 00:00:00 UTC+00:00
----End
Configuration Files
l Configuration file of Switch A
#
sysname SwitchA
#
vlan batch 10
#
interface XGigabitEthernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
stp disable
#
interface XGigabitEthernet0/0/2
port link-type trunk
port trunk allow-pass vlan 10
stp disable
#
interface XGigabitEthernet0/0/3
port link-type trunk
port trunk allow-pass vlan 10
smart-link flush receive control-vlan 10 password simple 123
#
smart-link group 1
restore enable
smart-link enable
port XGigabitEthernet0/0/1 master
port XGigabitEthernet0/0/2 slave
timer wtr 30
flush send control-vlan 10 password simple 123
#
monitor-link group 1
smart-link group 1 uplink
port XGigabitEthernet0/0/3 downlink 1
timer recover-time 10
#
return
l Configuration file of Switch B
#
sysname SwitchB
#
vlan batch 10
#
interface XGigabitEthernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
#
interface XGigabitEthernet0/0/3
port link-type trunk
port trunk allow-pass vlan 10
smart-link flush receive control-vlan 10 password simple 123
#
Quidway S6700 Series Ethernet Switches
Configuration Guide - Reliability 2 Smart Link and Monitor Link Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
45