Indicator Status Description
Steady on Ambient overtemperature protection
Ambient undertemperature protection
Internal overheating
Fan fault
AC input overvoltage, undervoltage,
phase failure, or severe voltage
imbalance
Slight or severe current imbalance
Incorrect or duplicate module
hardware address
Output capacitance imbalance
Output relay alarm
Poor output connection
Communication failure between the
charging module and external devices
Air
lter blockage alarm
Output short circuit alarm
Fault indicator
(red)
O Normal: The charging module is normal.
Steady on Lockout due to output overvoltage
Lockout due to output short circuit
Communication failure between the
primary side and the secondary side
Abnormal discharge circuit of the
output capacitance
Unrecoverable no-output breakdown
NO TE
If the charging module has no output due to mains failure (no AC input), the indicators
are o.
Indicators are not mutually exclusive. The three indicators can turn on at the same time
if conditions are met.
During software loading, the green, yellow, and red indicators turn on in turns. After the
loading is complete, all indicators stop blinking.
2.4.3 Nixie Tube Display
The nixie tubes display the current output voltage by default (000 is displayed
when there is no output). An error code is displayed when fault occurs.