Setting the Hardware Address
● To set the hardware address, you do not need to switch to the dEG mode.
● The hardware address settings of the charging module are saved upon power
failure.
Table 2-7 Procedure description
Procedure Operation Nixie Tube Display
1 Press the left or right button to
switch to the hardware address
display screen.
Adr (static)
2 Hold down the left or right button
to enter the hardware address
display screen.
Hardware address (decimal,
static)
3 Hold down the left or right button
to enter the hardware address
setting screen.
High-, middle-, or low-
order nixie tube blinking
(decimal)
4 Press the left button to switch
between the high-, middle-, and
low-order nixie tubes. Press the right
button to adjust the value.
Adjusted hardware address
(high-, middle-, or low-
order nixie tube blinking)
5 Hold down the left or right button
to save the settings.
Hardware address (static).
Then, the voltage display
screen is displayed.
Setting the Group Number
● To set the group number, you do not need to switch to the dEG mode.
● The group number settings of the charging module are saved upon power
failure (only for the company protocol).
Table 2-8 Procedure description
Procedure
Operation Nixie Tube Display
1 Press the left or right button to
switch to the group number display
screen.
GrP (static)
2 Hold down the left or right button
to enter the group number display
screen.
Group number
(decimal, static)
3 Hold down the left or right button
to enter the group number setting
screen.
Middle- or low-order
nixie tube blinking
(decimal)
R100020G1 Charging Module
User Manual 2 Overview
Issue 05 (2021-11-16) Copyright © Huawei Digital Power Technologies Co., Ltd. 15