Standard mode: The rated output power is 30 kW.
Display Panel
The display panel of the charging module consists of three indicators, three nixie
tubes, and two buttons.
The indicators show the running status of the charging module.
The nixie tubes display the output voltage, output current, hardware address,
group number, startup/shutdown status, software version, or error code of the
charging module.
The buttons allow you to set the output voltage, output current, hardware
address, and group number, and to start or shut down the charging module.
NO TE
If the hardware addresses of two charging modules are the same, an alarm is generated,
indicating duplicate hardware addresses.
Grouping and Address Allocation
You can set the groups for charging modules on the system monitoring
module. Charging modules in a group can automatically implement current
sharing control.
Software addresses are automatically allocated to the charging modules in a
group to facilitate module
identication. Note that the software address may
be
dierent from the slot number of the charging pile.
The hardware address of a charging module can be set to stay consistent with
the slot number of the charging pile. The charging module saves the
hardware address upon power-o.
NO TE
The software address will be reallocated after adding, reducing, or replacing a charging
module.
If an alarm is generated indicating that the hardware address of the module is duplicate
after the charging module is moved from one charging pile to another, reset the
hardware address rst and then the group number of that module. After the hardware
address is modied, the group number is restored to the default value.
2.2 Key Features
Wide input voltage range: 260–485 V AC
Wide operating temperature range: –35 to +75
Rated output voltage: 1000 V DC
Maximum output power: 30 kW
Hot swappable
Intelligent adjustment of fan speed
CAN bus communication
Alarm display on the LED and nixie tubes
Voltage adjustment, current limiting, and current sharing
R100030G1 Charging Module
User Manual 2 Product Description
Issue 05 (2021-11-16) Copyright © Huawei Digital Power Technologies Co., Ltd. 8