If cables are not connected as Figure 5-120 or Figure 5-121 shows, a server
reports alarm 1B01FFFF. Reconnect the cables to clear the alarm.
Prerequisites
Conditions
You have powered o the RH8100 V3. For details, see 6.2 Powering O the
RH8100 V3. Then you have removed all power cables from the server.
You have removed the front I/O module from the RH8100 V3. For details, see
5.8.1 Removing the Front I/O Module.
You have removed the supercapacitor tray. For details, see 5.8.9 Removing a
Supercapacitor.
Data
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for installing a RAID
controller card.
Tools
ESD gloves
M3 Phillips screwdriver
Packaging materials, for example, an ESD bag
Hardware
Spare RAID controller card
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see 1 Safety Instructions.
Step 2 Take the spare RAID controller card out of its ESD bag.
Step 3 Align the connector on the RAID controller card with the port on the mainboard,
and insert the RAID controller card slowly into the mainboard. See step (1) in
Figure 5-122.
Step 4 Tighten the screws on the RAID controller card. See step (2) in Figure 5-122.
RH8100 V3 Server
User Guide 5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 243