Sym
bol
Meaning Color Single-System Mode Dual-System Mode
Secondary
UID
button/
indicator
Blue This indicator is
unavailable and o,
and this button is
unavailable.
This button/indicator
helps identify and locate
system B in a cabinet.
You can turn on or o
the UID indicator by
manually pressing the
UID button or remotely
running a command on
the iBMC CLI.
●
O: System B is not
located.
● Steady on: System B is
located.
NOTE
To reset iBMC in system B,
hold down the UID button
for 4 to 6 seconds
Primary
health
indicator
Red
and
green
● Steady green: The
server is operating
properly.
● Blinking red at 1 Hz:
A major alarm is
generated.
● Blinking red at 2 Hz:
A critical alarm is
generated.
● Steady green: System
A is operating
properly.
● Blinking red at 1 Hz: A
major alarm is
generated for system
A.
● Blinking red at 2 Hz: A
critical alarm is
generated for system
A.
Secondary
health
indicator
Red
and
green
This indicator is
unavailable and o.
● Steady green: System
B is operating
properly.
● Blinking red at 1 Hz: A
major alarm is
generated for system
B.
● Blinking red at 2 Hz: A
critical alarm is
generated for system
B.
RH8100 V3 Server
User Guide 2 About the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 27