Figure 9-25 Installing a CPRI fiber optic cable
NOTICE
l To avoid any damage to fiber optic cables, the cables connected to the RRU must be installed
according to the installation process. For details about the installation process, see 9.3
Installation Process.
Step 3 Connect the end labeled 2A and 2B of the fiber optic cable to the optical module on the BBU
side.
Step 4 Route the cables according to the instructions in 9.1 Cabling Requirements, and then use cable
ties to bind the cables.
Step 5 Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End
9.12 Closing the Cover Plate of an RRU Cabling Cavity
This section describes the procedure for closing the cover plate of an RRU cabling cavity.
RRU3832&RRU3632
Installation Guide
9 Installing RRU Cables
Issue 05 (2014-06-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
110