NOTICE
l The diameter of a pole for installing an RRU ranges from 60 mm (2.36 in.) to 114 mm (4.49
in.). The recommended diameter is 80 mm (3.15 in.).
l When the diameter of a pole ranges from 60 mm (2.36 in.) to 76 mm (2.99 in.), a maximum
of three RRUs can be installed on the pole and the side-mounted installation is
recommended.
l Only a pole whose diameter ranges from 76 mm (2.99 in.) to 114 mm (4.49 in.) supports
more than three RRUs.
l The recommended thickness of the wall of a pole is 3.5 mm (0.14 in.) or above.
Figure 3-10 shows a single RRU installed on a pole.
Figure 3-10 A single RRU installed on a pole
Figure 3-11 shows two RRUs installed on a pole.
RRU3832&RRU3632
Installation Guide 3 Information About the Installation
Issue 05 (2014-06-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
18