2.6.3 NVMe SSD Indicators
Figure 2-20 shows the NVMe SSD indicators.
Figure 2-20 NVMe SSD indicators
Table 2-11 NVMe SSD indicators
Drive Activity
Indicator
(Green
Indicator)
Drive Fault
Indicator
(Yellow
Indicator)
State Description
O O The NVMe SSD cannot be detected.
Steady green O The NVMe SSD is detected and working
properly.
Blinking green
(2 Hz)
O Data is being read from or written to the
NVMe SSD.
O Blinking yellow
(2 Hz)
The NVMe SSD is being located or hot-
swapped.
O Blinking yellow
at 0.5 Hz
The NVMe SSD completes the hot removal
process and is removable.
Steady green or
o
Steady yellow The NVMe SSD is faulty.
2.7 Drive Backplane Connectors
Figure 2-21 shows connectors on the backplane for 12 x 3.5-inch drives in
pass-through mode.
TaiShan 200 Server
Maintenance and Service Guide (Model 2280) 2 Components
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 20