Power on the server using the Remote Virtual Console.
i. Log in to the Remote Virtual Console. For details, see 8.4.1 Logging
In to the Remote Virtual Console through the iBMC WebUI.
ii. On the KVM screen, click or on the menu bar.
iii. Choose Power On.
A dialog box is displayed.
iv. Click Yes to power on the server.
Power on the server using the iBMC CLI.
i. Log in to the iBMC CLI. For details, see 8.3 Logging In to the iBMC
CLI.
ii. On the iBMC CLI, run the ipmcset -d powerstate -v 1 command.
iii. Enter y or Y to power on the server.
5.4.2 Powering
O the Server
Services and programs running on the server will be interrupted when it is powered o.
Before powering o the server, ensure that all services and programs have been stopped
or switched to other servers.
Power-o in this section indicates to power o the server to the standby state (the
power indicator is steady yellow).
After the server is forcibly powered
o, wait for more than 10s to ensure that the server
is powered o completely. Then you can power it on again.
Power o the server using one of the following methods:
Use cables to connect the server to a video display, keyboard, and mouse, and
shut down the server OS to power o the server.
Press the power button on the front panel to power o the server. For details
about the power button position, see 2.1 Front Panel Components.
When the server is powered on, press the power button to shut down the
OS to power
o the server.
If the server OS is running, shut it down as prompted.
When the server is powered on, hold down the power button for 6
seconds to force the server to power
o.
NO TICE
A forced power-o may cause data loss or program damage. Forcibly
power
o the server only when necessary.
Power o the server using the iBMC WebUI.
a. Log in to the iBMC WebUI. For details, see 8.2 Logging In to the iBMC
WebUI.
TaiShan 200 Server
Maintenance and Service Guide (Model 2280) 5 Removal and Installation
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 76