Active Secure Firmware Version: 5.0.80.0 (21:21:55 Feb 29 2020)
Backup Secure Firmware Version: 5.0.80.0 (21:21:55 Feb 29 2020)
----------------- Product INFO -----------------
Product ID: 0x0007
Product Name: XXXX
BIOS Version: (U75)1.13
-------------- Mother Board INFO ---------------
Mainboard BoardID: 0x0005
Mainboard PCB: .A
------------------- NIC INFO -------------------
NIC 1 (TM280) BoardID: 0x0067
NIC 1 (TM280) PCB: .A
--------------- Riser Card INFO ----------------
Riser1 BoardName: BC82PRUN
Riser1 BoardID: 0x0093
Riser1 PCB: .A
Riser2 BoardName: BC82PRUN
Riser2 BoardID: 0x0093
Riser2 PCB: .A
-------------- HDD Backplane INFO --------------
Disk BP0 BoardName: BC82THBB
Disk BP0 BoardID: 0x004a
Disk BP0 PCB: .A
Disk BP0 CPLD Version: (U31)0.05
---------------- IO Board INFO ----------------
IOBoard0 ProductName: BC82IOEA
IOBoard0 BoardID: 0x0063
IOBoard0 PCB: .A
-------------------- PSU INFO -------------------
PS1 Version: DC:113 PFC:113
PS2 Version: DC:111 PFC:111
------------- Security Module INFO -------------
Specication Type: TPM/TCM
Specication Version: N/A
Manufacturer Name: N/A
Manufacturer Version: N/A
▪
CPLD Version: complex programmable logical device (CPLD) version
of the server
▪
BIOS Version: BIOS version of the server
▪
Active iBMC Version: active iBMC version of the server
▪
Backup iBMC Version: backup iBMC version of the server
e. Query the health status of the server.
iBMC:/->ipmcget -d health
System in health state
▪
If "System in health state" is displayed, no further action is required.
▪ If alarm information is displayed, go to the next step.
f. Check for generated alarms.
iBMC / # ipmcget -d healthevents
Event Num | Event Time | Alarm Level | Event Code | Event Description
1 | 2019-02-10 00:52:23 | Minor | 0x12000021 | get description failed.
2 | 2019-02-10 01:37:42 | Minor | 0x12000013 | Failed to obtain data of the air inlet
temperature.
3 | 2019-02-10 00:52:23 | Minor | 0x12000019 | Right mounting ear is not present.
4 | 2019-02-10 00:52:19 | Major | 0x28000001 | The SAS or PCIe cable to front disk
backplane is incorrectly connected.
g. Clear alarms. For details, see
TaiShan Rack Server iBMC Alarm
Handling
.
----End
TaiShan 200 Server (Model 2280)
User Guide 5 Installation and Conguration
Issue 09 (2021-01-12) Copyright © Huawei Technologies Co., Ltd. 102