Active Secure Firmware Version: 5.0.80.0 (21:21:55 Feb 29 2020)
Backup Secure Firmware Version: 5.0.80.0 (21:21:55 Feb 29 2020)
----------------- Product INFO -----------------
Product ID: 0x0007
Product Name: XXXX
BIOS Version: (U75)1.13
-------------- Mother Board INFO ---------------
Mainboard BoardID: 0x0005
Mainboard PCB: .A
------------------- NIC INFO -------------------
NIC 1 (TM280) BoardID: 0x0067
NIC 1 (TM280) PCB: .A
--------------- Riser Card INFO ----------------
Riser1 BoardName: BC82PRUN
Riser1 BoardID: 0x0093
Riser1 PCB: .A
Riser2 BoardName: BC82PRUN
Riser2 BoardID: 0x0093
Riser2 PCB: .A
-------------- HDD Backplane INFO --------------
Disk BP0 BoardName: BC82THBB
Disk BP0 BoardID: 0x004a
Disk BP0 PCB: .A
Disk BP0 CPLD Version: (U31)0.05
---------------- IO Board INFO ----------------
IOBoard0 ProductName: BC82IOEA
IOBoard0 BoardID: 0x0063
IOBoard0 PCB: .A
-------------------- PSU INFO -------------------
PS1 Version: DC:113 PFC:113
PS2 Version: DC:111 PFC:111
------------- Security Module INFO -------------
Specication Type: TPM/TCM
Specication Version: N/A
Manufacturer Name: N/A
Manufacturer Version: N/A
CPLD Version: complex programmable logical device (CPLD) version
of the server
BIOS Version: BIOS version of the server
Active iBMC Version: active iBMC version of the server
Backup iBMC Version: backup iBMC version of the server
e. Query the health status of the server.
iBMC:/->ipmcget -d health
System in health state
If "System in health state" is displayed, no further action is required.
If alarm information is displayed, go to the next step.
f. Check for generated alarms.
iBMC / # ipmcget -d healthevents
Event Num | Event Time | Alarm Level | Event Code | Event Description
1 | 2019-02-10 00:52:23 | Minor | 0x12000021 | get description failed.
2 | 2019-02-10 01:37:42 | Minor | 0x12000013 | Failed to obtain data of the air inlet
temperature.
3 | 2019-02-10 00:52:23 | Minor | 0x12000019 | Right mounting ear is not present.
4 | 2019-02-10 00:52:19 | Major | 0x28000001 | The SAS or PCIe cable to front disk
backplane is incorrectly connected.
g. Clear alarms. For details, see
TaiShan Rack Server iBMC Alarm
Handling
.
----End