Paramet
er
Descripti
on
Value
<option>
Serial
port
direction
The value options of this parameter and the value
meanings vary according to the server model. You
are advised to run the ipmcget -d serialdir
command to view the value options.
For the server, the options are as follows:
0: sets the serial port on the server panel as the
system serial port.
1: sets the serial port on the server panel as the
iBMC serial port.
2: sets the SOL port as the system serial port.
3: sets the SOL port as the iBMC serial port.
4: sets the serial port on the SDI V3 card panel as
an SCCL port.
5: sets the serial port on the SDI V3 card panel as
an IMU port.
6: sets the serial port on the SDI V3 card panel as
an SCCL port.
7: sets the serial port on the SDI V3 card panel as
an IMU port.
To set the panel serial port as the iBMC serial port,
run the ipmcset -d serialdir -v 1 command.
NOTE
If no SDI V3 is installed in a server, <option> can be 0
to 3 only.
If one SDI V3 card is installed, the values 4 and 5 are
available for setting the ports on the SDI V3 in I/O
module 1 or 2.
If two SDI V3 cards are installed, the values 4 to 7 are
available. The values 4 and 5 are used for setting the
ports on the SDI V3 in I/O module 1, while the values 6
and 7 are for the ports on the SDI V3 in I/O module 2.
To set the serial port by using a jumper, do as follows:
a. Power o the server and remove the power cables.
b. Place the jumper cap on COM_SW pins. For details about the jumper
position, see Figure 8-16.
TaiShan 200 Server (Model 2280)
User Guide 8 Common Operations (iBMC V250 or Later)
Issue 09 (2021-01-12) Copyright © Huawei Technologies Co., Ltd. 137