Silkscr
een
Indicator/
Button
State Description
Power
button/
indicator
Power indicator
● Steady yellow: The server is in the standby state.
● Steady green: The server is properly powered on.
● Blinking yellow: The iBMC is starting.
● O: The server is not connected to a power source.
Power indicator
● When the server is powered on, you can press this
button to shut down the OS.
● When the server is powered on, you can hold down
this button for 6 seconds to force the server to power
o.
● When the server is in the standby state, you can press
this button to start the server.
UID
button/
indicator
The UID button/indicator helps identify and locate a
device.
UID indicator:
● O: The device is not being located.
● Blinking blue (blinking 255 seconds): The device has
been located and is
dierentiated from other devices
that have also been located.
● Steady blue: The device is being located.
UID button:
● You can turn on, turn
o, or blink the UID indicator by
pressing the UID button on the panel or by using the
iBMC CLI or WebUI.
● You can press this button to turn on or
o the UID
indicator.
● You can press and hold down this button for about 5
seconds to reset the iBMC.
Health
indicator
● Steady green: The server is operating properly.
● Blinking red at 1 Hz: A major alarm has been
generated on the server.
● Blinking red at 5 Hz: A critical alarm has been
generated on the server.
FlexIO
presence
indicators
(1 and 2)
● 1 and 2: represent FlexIO cards 1 and 2 respectively.
● Steady green: The FlexIO card is installed and can be
identied.
● O: The FlexIO card is not installed or faulty.
TaiShan 200 Server (Model 2280)
User Guide 2 Components
Issue 09 (2021-01-12) Copyright © Huawei Technologies Co., Ltd. 14