Loading...
Table 3-3 Operating temperature limitations
Model Max. 30°C
(86°F)
Max. 35°C (95°F)
(ASHRAE Class A2
Compliant)
Max. 40°C (104°F)
(ASHRAE Class A3
Compliant)
12 x 3.5"
drive EXP
conguratio
n
Supports all
options.
Supports all
options.
Options not supported:
64-core CPUs
PCIe SSD cards
Passive GPU cards
(including DMINI
cards)
Rear drives
Kunpeng 920 7265 or
5255 processors
12 x 3.5"
drive pass-
through
conguratio
n
25 x 2.5"
drive EXP
conguratio
n
24 x 2.5"
drive pass-
through
conguratio
n
8 x 2.5" SAS/
SATA + 12 x
2.5" NVMe
drive
conguratio
n
Supports all
options.
Supports all
options.
Not supported
8 x 2.5"
drive
conguratio
n
Supports all
options.
Supports all
options.
Kunpeng 920 7265 or
5255 processors are not
supported.
NOTE
If one fan fails, the highest operating temperature of the server is 5°C (9°F) lower than
that in normal cases.
When powered by Kunpeng 920 5220 or 3210 processors, the server does not support
24 x 2.5" SAS/SATA pass-through drive
conguration or 8 x 2.5" drive conguration.
TaiShan 200 Server (Model 2280)
User Guide 3 Product Specications
Issue 09 (2021-01-12) Copyright © Huawei Technologies Co., Ltd. 38

Table of Contents