3.3 Physical Specications
Physical Specications
Table 3-4 Physical specications
Item Description
Dimensions
(H x W x D)
Chassis with 3.5-inch drives: 86.1 mm (2U) x 447 mm x 790 mm
(3.39 in. x 17.60 in. x 31.10 in.)
Chassis with 2.5-inch drives: 86.1 mm (2U) x 447 mm x 790 mm
(3.39 in. x 17.60 in. x 31.10 in.)
Installation
space
Requirements for cabinet installation (cabinet compliant with
the International Electrotechnical Commission (IEC) 297
standard):
● Cabinet width: 482.6 mm (19 in.)
● Cabinet depth: ≥ 1000 mm (39.37 in.)
Requirements for guide rail installation:
● L-shaped guide rails: apply only to Huawei cabinets.
● Adjustable guide rails: apply to a cabinet with a distance of
543.5 mm to 848.5 mm (21.40 in. to 33.41 in.) between the
front and rear mounting bars.
Weight in full
conguration
Net weight:
● Server with 12 x 3.5-inch front drives + 4 x 3.5-inch rear
drives + 4 x 2.5-inch rear drives: 32 kg (70.55 lb)
● Server with 25 x 2.5-inch front drives + 2 x 3.5-inch rear
drives + 4 x 2.5-inch rear drives: 25 kg (55.12 lb)
● Server with 8 x 2.5-inch SAS/SATA front drives + 12 x 2.5-inch
front NVMe SSDs + 4 x 2.5-inch rear drives: 24 kg (52.91 lb)
● Server with 24 x 2.5-inch front drives + 4 x 2.5-inch rear
drives: 24 kg (52.91 lb)
● Server with 8 x 2.5-inch front drives + 4 x 2.5-inch rear drives:
19.4 kg (42.77 lb)
Packaging materials: 5 kg (11.03 lb)
Power
consumption
The power consumption parameters vary according to
congurations (including the ErP standard conguration of the
European Union). Use the Computing Product Power
Calculator to obtain the specic power consumption value.
3.4 PSU Specications
● The PSUs are hot-swappable and work in 1+1 redundancy mode.
TaiShan 200 Server (Model 2280)
User Guide 3 Product Specications
Issue 09 (2021-01-12) Copyright © Huawei Technologies Co., Ltd. 39