Figure 5-29 Querying alarm information (iBMC V549 or earlier)
▪ If the iBMC version is V561 or later, view Alarm Statistics on the
Home page, as shown in Figure 5-30.
Figure 5-30 Querying alarm information (iBMC V561 or later)
d. Clear any alarms if present. For details, see the
TaiShan Rack Server
iBMC Alarm Handling
.
● Check the server using the iBMC CLI.
a. Set an IP address for the PC. This IP address must be on the same
network segment as the iBMC management network port.
b. Connect a network cable from the PC to the iBMC management network
port of the server.
c. Start a Secure Shell (SSH, PuTTY), tool on the PC and log in with the IP
address of the iBMC management network port and iBMC user name and
password.
By default, SSH is used to log in to the iBMC. If the SSH service is disabled,
enable it by choosing Conguration > Services on the iBMC WebUI.
d. Run the ipmcget -d ver command to view the server version information.
Check that the server versions meet site requirements.
iBMC:/->ipmcget -d ver
------------------- iBMC INFO -------------------
IPMC CPU: Hi1710
IPMI Version: 2.0
CPLD Version: (U6076)1.00
Active iBMC Version: (U68)3.32
Active iBMC Build: 003
Active iBMC Built: 14:32:33 Apr 15 2019
Backup iBMC Version: 3.32
SDK Version: 3.26
SDK Built: 10:53:30 Mar 18 2019
Active Uboot Version: 2.1.13 (Dec 24 2018 - 20:23:20)
Backup Uboot Version: 2.1.13 (Dec 24 2018 - 20:23:20)
----------------- Product INFO -----------------
Product ID: 0x0001
Product Name: XXXX
iME Version: 0.66
BIOS Version: (U75)0.90
TaiShan 200 Server (Model 2280)
User Guide 5 Installation and Conguration
Issue 09 (2021-01-12) Copyright © Huawei Technologies Co., Ltd. 73