Step 9 Enter the new password again.
If the command output is as follows, the password has been changed:
. done
Un-Protected 1 sectors
Erasing Flash...
. done
Erased 1 sectors
Writing to Flash... done
. done
Protected 1 sectors
password be changed successfully.
Step 10 Run the following command to exit U-boot:
boot
----End
5.11.7
Conguring RAID
Step 1 Log in to the iBMC WebUI. For details, see 5.11.4 Logging In to the iBMC WebUI.
Step 2 Query RAID controller card information.
If the iBMC version is V549 or earlier, choose Information > System Info >
Other Devices. The page shown in Figure 5-35 is displayed.
Figure 5-35 RAID controller card information (iBMC V549 or earlier)
If the iBMC version is V561 or later, choose System > Storage Management.
The page shown in Figure 5-36 is displayed.
Figure 5-36 RAID controller card information (iBMC V561 or later)
NO TE
The information shown in Figure 5-36 is for reference only. The actual information
may
dier.
Step 3 Congure a RAID array.
TaiShan 200 Server (Model 2280)
User Guide 5 Installation and Conguration
Issue 09 (2021-01-12) Copyright © Huawei Technologies Co., Ltd. 78

Table of Contents