Item Specications
Voltage range Upper threshold: +10%, +15%, +20%, or
+25% at 220 V AC
Upper threshold: +10%, +15%, or +20% at
230 V AC
Upper threshold: +10% or +15% at 240 V AC
Lower threshold: –10%, –20%, –30%, –40%, –
50%, or –60%
Rated frequency 50 Hz/60 Hz
Frequency range 50/60±6 Hz (adjustable with a tolerance of 0.5–6
Hz, ±2 Hz by default)
Input system Supports only one power source.
Overvoltage category OVC II
Table 3-5 Output electrical specications
Item
Specications
Power system Single-phase, three-wire
Rated output voltage 220 V AC/230 V AC/240 V AC
Output power factor 1
Output voltage tolerance ±1%
Output short-circuit current 6K: Ipeak: 3.5 kA; Irms: 2.5 kA
10K: Ipeak: 4.0 kA; Irms: 3.0 kA
Voltage distortion Linear load THD < 1% @ Input voltage THDv
< 5%
Non-linear load THD < 3% @ Input voltage
THDv < 5%
UPS2000-H-(6 kVA-10 kVA)
User Manual 3 Technical Specications
Issue 03 (2023-08-20) Copyright © Huawei Digital Power Technologies Co., Ltd. 45