Table 6-4 Description of each field in the format of alarms
Field Indication Description
TimeStamp Time to send out the
information
Five timestamp formats are available:
l boot: indicates relative time. By default,
debugging information adopts this timestamp
format.
l date: indicates the timestamp in the format of
system time. By default, logs and traps adopt
this timestamp format.
l short-date: indicates system time. The short-
date format does not contain year information.
l format-date: indicates another format of system
time.
l none: indicates that no timestamp is contained
in traps.
The timestamp and the host name are separated by
a blank space.
HostName
Host name By default, the name is Quidway.
There is a space between the sysname and module
name.
ModuleName Module name Indicates the name of the module that generates an
alarm.
Severity Severity of
information
Indicates the severity of alarms:
l Critical
l Major
l Minor
l Warning
l Indeterminate
l Cleared
Brief
Brief information Provides brief information of the alarms.
Description Description Provides a detailed description of the alarms.
6.2 Configuring the Information Center
This section describes how to manage and configure the information center.
Quidway S5700 Series Ethernet Switches
Configuration Guide - Device Management 6 Monitoring the Device Through the Information Center
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
54