v 1.0 — August 2018 Altanium Neo5
Page 128
14.2.3 Input Connector Pin-Out
The table that follows shows the connection detail for all the inputs wired for dry contacts
(No voltage).
CAUTION!
Electrical hazard - risk of damage to the equipment. DO NOT apply a voltage to any of
the Inputs. Doing so could damage the Neo5.
Digital Inputs (Wiring for Dry or No Voltage Contacts)
Connector/Pin Field Cable Wire Color Signal Function
Input / 1 Black
Remote Standby
Input / 2 Red
Input / 3 White
Remote Boost
Input / 4 Green
Input / 5 Orange
Remote Start
Input / 6 Blue
Input / 7 Brown
Remote Stop
Input / 8 Yellow
Input / 9 Violet Not Used