v 1.0 — August 2018 Altanium Neo5
Page 138
15.3.1 Replacing an Intelligent Control Card
1. Locate the Card Cage that contains the faulty Intelligent Control Card.
IMPORTANT!
Although they look similar, X-Series and H-Series cards use different backplanes and
are not compatible with each other.
IMPORTANT!
You must have an Intelligent Control Card present in the position labeled 1 in all
backplanes for the system to function properly.
WARNING!
Electrical and mechanical hazard - risk of death, serious injury and/or damage to the
equipment. Turn off all power to the system and disconnect it completely from the
main input power. Follow the local Lock Out Tag Out procedures.
The ICC2 and ICC3 cards are electrostatic discharge sensitive. Use a ground strap when
handling the cards.