17 HUSKYTOOLS.com
Please contact 1-888-43-HUSKY for further assistance.
Problem Possible Cause Solution
The compressor does not run. There is a loss of power or
the motor is overheated.
Check for proper use of extension
cord.
There is no power to the unit. Check to be sure the unit is plugged
in.
The circuit breaker has
tripped or a fuse has blown
at the main power source.
Check the fuse/breaker.
The thermal overload
protector is actuated.
Turn the air compressor OFF ( O ).
Unplug air compressor and wait until
compressor cools down.
Plug the air compressor into an
approved outlet.
Turn the air compressor ON ( I ).
The pressure switch is bad. Bring the compressor to a service
center.
The compressor has reached
automatic shutoff pressure.
Release the air from the tank until the
compressor restarts automatically.
The motor hums while
running slowly, or it doesn’t
run at all.
There is low voltage from the
power source.
Call an electrician.
The wrong gauge wire or
length of extension cord is
being used.
Check for proper gauge wire and cord
length.
There is a shorted or open
motor wiring.
Bring the compressor to a service
center.
There is a defective check
valve or unloader.
Bring the compressor to a service
center.
Troubleshooting