4.7 PREPARE THE PRV FOR PEGASUS PRESSURE TRANSDUCERS
The PRV valve should be fitted
with service taps that allow
maintenance whilst the PRV is in
operation.
An example is shown opposite.
Choose locations to be used for
attaching the Pegasus pressure
transducers and also the water
feed to the Pegasus “Inlet” port.
Ensure these service taps are
closed to allow work to proceed.
Fit Y-adaptors or quick-release
connectors to the PRV, as
required, to allow connection to
Pegasus2 at a later stage.
Do not fit any pressure transducers or hoses to the PRV at this stage.
Stop Taps (for service):
Close those required for transducers and
water feed to “Inlet” of Pegasus inlet.