- 16 -
Troubleshooting Continued
Problem
Cause
Solution
Vacuum
Motor Not
Running
Building circuit breaker
tripped. Reset breaker or move
cord to other outlet
Building circuit breaker tripped. Reset breaker or
move cord to other outlet
Faulty power cord Replace cord
Faulty switch or internal
wiring Check wiring & test
switch
Repair as needed *
Vacuum motor faulty Replace vacuum motor
Loss of
Vacuum
Vacuum motor faulty Replace vacuum motor
Vacuum motor gasket
damaged
Replace gasket
Recovery tank lid gasket
damaged
Replace lid assembly or gasket
Vacuum hose or tool clogged Clean out vacuum hoses and tool
Vacuum hoses or cuffs leaking
Replace vacuum hoses, cuffs & connectors as
needed
Recovery tank full Drain tank
Float shutoff filter clogged Clean float shutoff filter
Float shutoff stuck Repair or replace float shutoff
Recovery tank damaged Replace recovery tank
Tool won't
spray - slow or
uneven spray
Jet clogged Clean out or replace jet
Inline filter clogged Clean out or replace filter if so equipped
Jet worn Replace jet
Jet not aligned properly Re-align jet
Tool valve faulty Repair or replace valve
Quick connects or hoses
restricted
Clean out or replace quick connects and/or hoses
Pump not pumping
See Troubleshooting sections relating to solution
pump