TORCH LEAD REPLACEMENT
4 Field Service Bulletin
Right side of
handle
Left side of
handle
Torch lead
Handle
screws
Safety trigger
and spring
Torch body
Cap-sensor
switch
Start
switch
Pilot wire
terminal screw
Gas fitting
Torch lead
Handle
screws
Safety trigger
and spring
Torch body
Cap-sensor
switch
Right side of
handle
Left side of
handle
Start
switch
Pilot wire
terminal screw
Gas fitting
Figure 1 Duramax 75°/HRT/HRT
2
Figure 2 Duramax 15°/HRTs

Other manuals for Hypertherm Duramax Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Duramax Series and is the answer not in the manual?

Hypertherm Duramax Series Specifications

General IconGeneral
CoolingAir-cooled
TypePlasma cutting torch
SeriesDuramax
CompatibilityPowermax systems
Torch Lengths15' (4.6 m), 25' (7.6 m)
ConsumablesNozzles, electrodes, shields, retaining caps, swirl rings
Torch ModelsDuramax Lock
Compatible SystemsPowermax65, Powermax85, Powermax105
Nozzle TypesFineCut
Electrode TypesStandard
Shield TypesStandard
Length15 ft (4.6 m) standard, 25 ft (7.6 m) optional