EasyManua.ls Logo

Hytera MD78X - Page 450

Hytera MD78X
519 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting Flow Chart
VHF (136MHz
174MHz)
34
Check FGU
U915 outputs 5 V and
U918 outputs 3.3 V?
Replace U915 or
U918
No
Q104 outputs 4.3 V?
Yes
Check Q104
No
Yes
VCO oscillates?[1]
Q108, Q112, Q101, and
Q105 work normally?
[2]
No
Replace Q106,
Q110,
Q100, and Q103
Yes
Check D107, D108, D109, D110,
D121, D122, D125, and D126
No
TP124 CV is normal?[4]
Yes
PLL U100 is normal?
[5]
Yes
No
Replace PLL U100
No
Check U101, U102,
R187, and R171
TP109 feedback is
normal?[6]
Yes
Yes
Check the feedback
circuit
Check CPU data circuit
Yes
No
End
Q106, Q110, Q100, and
Q103 work normally?
[3]
No
Replace Q108,
Q112,
Q101, and Q105
Oscillates (19.2 MHz)?[7]
Yes
Check 19.2MHz
oscillator circuit
No
Description of normal situations:
[1] The oscillation frequency of RX TP123 and TX TP111 can be detected.
[2] Q108, Q112, Q101, and Q105 are turned on and output about 4.3 V.
[3] The difference between the emitter voltage and base voltage as for Q106, Q110, Q100 and Q103 is
about 0.7 V.
[4] The CV of TP124 ranges from 0.5 V to 4.5 V.
[5] PLL U100 is supplied by 5 V and 3.3 V normally.
[6] The power from TP109 to PLL is about -13 dBm.
[7] TP100 outputs 19.2 MHz signal.

Table of Contents